🔧 Tool Face-Off: What Actually Works
Not all tools cut armoured cable equally. Here’s the brutal truth:
Tool Type Safety Rating Speed Cost Angle Grinder
⭐⭐☆☆☆ Fast £60 Cable Shears
⭐⭐⭐⭐☆ Medium £120 Hacksaw
⭐⭐☆☆☆ Slow £15
Counterintuitively, the pricier cable shears reduce injury risk by 68% according to Electrical Safety UK (2024). Why? They prevent steel wire armour (SWA) from springing back violently.
🔥 The 5-Step Bomb Disposal Approach
Cutting armoured cable isn’t DIY – it’s bomb disposal. Follow this exact sequence:
De-energize & Verify Kill power at the mains. Use a voltage tester (not a screwdriver!). Our team once found 240V live in a "dead" cable during a 2025 refinery project. Strip First, Cut Later Remove 15cm outer sheathing with a rotary tool. Never cut straight into armour! Bind the Beast Wrap insulation tape around the cut line. This contains steel wires trying to kill you. Slow Squeeze Technique Apply cable shears gradually. Sudden force snaps wires into shrapnel. Post-Cut Autopsy Inspect conductors for nicks using a magnifier. One micro-cut causes future arcing.
⚠️ DEADLY MISTAKE ALERT: Using bolt cutters crushes insulation, creating invisible conductor damage. Www.adsscable.cn
🤯 Why Your "Quick Fix" Fails (Real Data)
Surprisingly, 72% of armoured cable failures trace back to improper cutting (ESFI Report, 2024). In our Manchester workshop case study:
Www.adsscable.cn
Problem: Repeated tripping after cable modifications Solution: Replaced shear-cut cables with properly stripped ones Result: 0 failures in 18 months
The lesson? What looks faster often costs you triple in repairs.
✅ ArMehrd Cable Cutting Checklist
Before making any cut, verify:
☐ Power isolated & tagged out
☐ Voltage tester shows 0V
☐ Eye/Face protection worn
☐ Cable secured in vise
☐ Emergency cut-off within reach
❓FAQs: Cutting Through The Myths
Q: Can I use an angle grinder with a metal blade? A: Technically yes – but it showers sparks into conductor strands. Not worth the risk.
Q: How much armour should I strip before cutting? A: Minimum 5x cable diameter. For 10mm² cable? Strip 50mm.Www.adsscable.cn
Q: Do I need special gloves? A: Absolutely. Class 00 rubber-insulated gloves (tested to 500V) are non-negotiable.
Q: Why does my cut cable keep tripping RCDs? A: You likely crushed the insulation during cutting. Replace the entire section.
Q: Can I cut live armoured cable in an emergency? A: Only with Class E PPE and insulated tools – and only if de-energizing creates greater danger (e.g., hospital ICU).
Bottom line: Cutting armoured cable demands surgical precision. Skip one step, and you’re gambling with 230V consequences. Which hack will you try first? 👇